Antminer S19

BTC mining on the RuPool pool · 120 TH/s, 2,760 W

≈ $3.45/day · covers power up to $0.052/kWh

Start mining

After sign-up your cabinet opens a step-by-step connection guide.

Specifications

ModeHashratePowerEfficiency
Antminer S19k Pro 120 TH/sprimary120 TH/s2,760 W23 J/TH
Antminer S19j Pro 104 TH/s104 TH/s3,068 W29.5 J/TH
Antminer S19 XP 141 TH/s141 TH/s3,010 W21.3 J/TH
Antminer S19 Pro 110 TH/s110 TH/s3,250 W29.5 J/TH
Antminer S19 95 TH/s95 TH/s3,250 W34.2 J/TH
Manufacturer
Bitmain
Algorithm
SHA-256
Cooling
Air
Release year
2020
Noise level
75 dB
Voltage
200–240
Dimensions
400 × 195 × 290 mm

Specification source

Profitability

ModeMined per dayRevenue per dayRevenue per monthPower useCovers power
Antminer S19k Pro 120 TH/s0.00005513 BTC$3.45$103.4366.2 kWhup to $0.052/kWh
Antminer S19j Pro 104 TH/s0.00004778 BTC$2.99$89.6473.6 kWhup to $0.041/kWh
Antminer S19 XP 141 TH/s0.00006477 BTC$4.05$121.5372.2 kWhup to $0.056/kWh
Antminer S19 Pro 110 TH/s0.00005053 BTC$3.16$94.8178 kWhup to $0.041/kWh
Antminer S19 95 TH/s0.00004364 BTC$2.73$81.8878 kWhup to $0.035/kWh

Net profit, mode “Antminer S19k Pro 120 TH/s”

TariffProfit per dayProfit per month
$0.05/kWh$0.14$4.07
$0.08/kWh-$1.85-$55.55
$0.12/kWh-$4.50-$135.04

Calculated on 18 November 2026. Pool fee included. Rate: 1 BTC = $62,539.90.

Precise estimate in the profitability calculator

RuPool setup

Pool address, login and password to connect Antminer S19.

Recommended address — automatic location pick with failover

stratum+tcp://enter.rupool.pro:3333
Other ports (if the main one is blocked by your ISP)
stratum+tcp://enter.rupool.pro:8888
stratum+tcp://enter.rupool.pro:443
stratum+tcp://enter.rupool.pro:25
stratum+ssl://enter.rupool.pro:999
Addresses by location

Moscow (whitelist)

stratum+tcp://msk-ru.enter.rupool.pro:3333
Other ports (if the main one is blocked by your ISP)
stratum+tcp://msk-ru.enter.rupool.pro:8888
stratum+tcp://msk-ru.enter.rupool.pro:443
stratum+tcp://msk-ru.enter.rupool.pro:25
stratum+ssl://msk-ru.enter.rupool.pro:999

Moscow

stratum+tcp://msk2-ru.enter.rupool.pro:3333
Other ports (if the main one is blocked by your ISP)
stratum+tcp://msk2-ru.enter.rupool.pro:8888
stratum+tcp://msk2-ru.enter.rupool.pro:443
stratum+tcp://msk2-ru.enter.rupool.pro:25
stratum+ssl://msk2-ru.enter.rupool.pro:999

Novosibirsk

stratum+tcp://nsk-ru.enter.rupool.pro:3333
Other ports (if the main one is blocked by your ISP)
stratum+tcp://nsk-ru.enter.rupool.pro:8888
stratum+tcp://nsk-ru.enter.rupool.pro:443
stratum+tcp://nsk-ru.enter.rupool.pro:25
stratum+ssl://nsk-ru.enter.rupool.pro:999

Helsinki

stratum+tcp://hel-fi.enter.rupool.pro:3333
Other ports (if the main one is blocked by your ISP)
stratum+tcp://hel-fi.enter.rupool.pro:8888
stratum+tcp://hel-fi.enter.rupool.pro:443
stratum+tcp://hel-fi.enter.rupool.pro:25
stratum+ssl://hel-fi.enter.rupool.pro:999

Almaty

stratum+tcp://ala-kz.enter.rupool.pro:3333
Other ports (if the main one is blocked by your ISP)
stratum+tcp://ala-kz.enter.rupool.pro:8888
stratum+tcp://ala-kz.enter.rupool.pro:443
stratum+tcp://ala-kz.enter.rupool.pro:25
stratum+ssl://ala-kz.enter.rupool.pro:999
Login (worker):own.K120x62

Format: <subaccount>.<worker>. Get your subaccount in the cabinet.

Password:anything

How to set up Antminer S19 on the pool

  1. Find the miner IP

    Find the ASIC IP address in your router's DHCP client list, or press the IP Report button on the miner itself.

  2. Open the web interface

    Enter the IP address in a browser on a computer on the same network.

  3. Log in to the panel

    Default login and password on stock firmware are root / root.

  4. Open the pool settings

    Go to Miner Configuration → General Settings, the Pool 1, Pool 2, Pool 3 block.

  5. Fill in the pool addresses

    Pool 1 — the recommended address (auto-select), Pool 2 and Pool 3 — two nearest locations. Worker — your login in the form subaccount.worker, Password — anything.

  6. Save and check

    Press Save & Apply, wait for the restart and check share submission on the Miner Status tab; accruals appear in the cabinet.

The S19 family is the workhorse of the used ASIC market. It started with the S19 and S19 Pro in 2020 and ended with the S19k Pro in 2023, with the S19j Pro and S19 XP in between. Pick your exact variant in the table and the live revenue estimate adjusts to its hashrate.

The honest math: efficiency ranges from about 34 J/TH on the original S19 to about 21 J/TH on the S19 XP, while current-generation machines sit around 17 J/TH or lower. After the 2024 halving, your electricity price per kWh decides whether an S19 is still worth plugging in. Early units need very cheap power; the S19k Pro and S19 XP tolerate more.

On RuPool every S19 variant mines Bitcoin (SHA-256) under FPPS, so you are paid for each accepted share at the pool rate instead of waiting for blocks.

All air-cooled S19 models use the APW12 power supply rated for 200–240 V single-phase, drawing roughly 2.8 to 3.3 kW depending on the variant. In North America that means a dedicated 240 V circuit; a 120 V outlet will not work. The PSU has two AC inlets, so plan for two cords per unit.

Four fans push about 75 dB. In a garage or shed you need a clear intake and exhaust path; dust buildup and summer heat are the two main reasons an S19 drops below its rated hashrate. Hydro versions such as the S19 XP Hyd. are separate products with three-phase power and are not covered here.

When buying used, efficiency matters more than the badge: an S19 XP or S19k Pro produces the same terahash for much less energy than an original S19. Check that all three hashboards report in the web interface before you pay.

Stock Bitmain firmware works fine. The S19 is also the most common target for third-party firmware with underclocking and autotuning; that is your decision. RuPool accepts any firmware that uses standard stratum.

Frequently asked questions

Is the Antminer S19 still profitable in 2026?

It depends on your power price and the variant. The S19k Pro and S19 XP can still run at moderate electricity rates; an original S19 or S19 Pro generally needs very cheap power. Compare the live FPPS revenue on this page with your daily energy cost.

How do I calculate my electricity cost for an S19?

Multiply the wall power of your variant by 24 and divide by 1000 to get kWh per day, then multiply by your rate. For example, a 3250 W S19 Pro uses 78 kWh a day. Compare that with the live revenue shown above.

Which used S19 variant is the best buy?

The lower the J/TH, the longer it stays viable. The S19 XP and S19k Pro are the most efficient; the S19j Pro is the most common and usually the cheapest. Whatever you choose, verify that all hashboards work before buying.

Can I run an S19 on 120 V?

No. The stock APW12 power supply is rated for 200–240 V. In the US and Canada you need a 240 V circuit sized by an electrician for continuous load.

How do I set the stratum URL on an S19?

Open the miner's IP in a browser, go to the miner configuration page, paste a RuPool stratum address from this page, set the worker as subaccount.worker and use any password. Save and the worker appears in your dashboard within minutes.

What firmware should I run on an S19?

Stock Bitmain firmware is the safe default. Third-party firmware can lower power draw or tune per chip, but it affects warranty and is your responsibility. RuPool works with any standard stratum firmware.

Connect Antminer S19 to RuPool

Sign up — your cabinet opens a step-by-step guide: create a subaccount, set a payout address and enter the stratum address in the miner.

Daily payouts, 1% FPPS fee, 24/7 support.

Start mining