LTC and DOGE mining (merged mining) on the RuPool pool · 20 GH/s, 3,680 W
≈ $7.07/day · covers power up to $0.08/kWh
After sign-up your cabinet opens a step-by-step connection guide.
| Mode | Hashrate | Power | Efficiency |
|---|---|---|---|
| Antminer L11 20 GH/sprimary | 20 GH/s | 3,680 W | 184 J/GH |
| Antminer L11 Pro 21 GH/s | 21 GH/s | 3,612 W | 172 J/GH |
| Mode | Mined per day | Revenue per day | Revenue per month | Power use | Covers power |
|---|---|---|---|---|---|
| Antminer L11 20 GH/s | 0.02527521 LTC102.096644 DOGE | $7.07 | $211.96 | 88.3 kWh | up to $0.08/kWh |
| Antminer L11 Pro 21 GH/s | 0.02653897 LTC107.2014762 DOGE | $7.42 | $222.56 | 86.7 kWh | up to $0.086/kWh |
LTC and DOGE are mined at the same time on the same hashrate (merged mining) — the income adds up.
| Tariff | Profit per day | Profit per month |
|---|---|---|
| $0.05/kWh | $2.65 | $79.48 |
| $0.08/kWh | -$0.00 | -$0.00 |
| $0.12/kWh | -$3.53 | -$105.99 |
Calculated on 18 November 2026. Pool fee included. Rate: 1 LTC = $43.68, 1 DOGE = $0.05839.
Precise estimate in the profitability calculatorPool address, login and password to connect Antminer L11.
Recommended address — automatic location pick with failover
stratum+tcp://enter.rupool.pro:3334stratum+tcp://enter.rupool.pro:8889stratum+tcp://enter.rupool.pro:444stratum+tcp://enter.rupool.pro:26stratum+ssl://enter.rupool.pro:998Moscow (whitelist)
stratum+tcp://msk-ru.enter.rupool.pro:3334stratum+tcp://msk-ru.enter.rupool.pro:8889stratum+tcp://msk-ru.enter.rupool.pro:444stratum+tcp://msk-ru.enter.rupool.pro:26stratum+ssl://msk-ru.enter.rupool.pro:998Moscow
stratum+tcp://msk2-ru.enter.rupool.pro:3334stratum+tcp://msk2-ru.enter.rupool.pro:8889stratum+tcp://msk2-ru.enter.rupool.pro:444stratum+tcp://msk2-ru.enter.rupool.pro:26stratum+ssl://msk2-ru.enter.rupool.pro:998Novosibirsk
stratum+tcp://nsk-ru.enter.rupool.pro:3334stratum+tcp://nsk-ru.enter.rupool.pro:8889stratum+tcp://nsk-ru.enter.rupool.pro:444stratum+tcp://nsk-ru.enter.rupool.pro:26stratum+ssl://nsk-ru.enter.rupool.pro:998Helsinki
stratum+tcp://hel-fi.enter.rupool.pro:3334stratum+tcp://hel-fi.enter.rupool.pro:8889stratum+tcp://hel-fi.enter.rupool.pro:444stratum+tcp://hel-fi.enter.rupool.pro:26stratum+ssl://hel-fi.enter.rupool.pro:998Almaty
stratum+tcp://ala-kz.enter.rupool.pro:3334stratum+tcp://ala-kz.enter.rupool.pro:8889stratum+tcp://ala-kz.enter.rupool.pro:444stratum+tcp://ala-kz.enter.rupool.pro:26stratum+ssl://ala-kz.enter.rupool.pro:998own.sid2009Format: <subaccount>.<worker>. Get your subaccount in the cabinet.
Connect to the LTC stratum — DOGE is credited automatically (merged mining). No separate DOGE address or wallet is needed to connect.
Find the miner IP
Find the ASIC IP address in your router's DHCP client list, or press the IP Report button on the miner itself.
Open the web interface
Enter the IP address in a browser on a computer on the same network.
Log in to the panel
Default login and password on stock firmware are root / root.
Open the pool settings
Go to Miner Configuration → General Settings, the Pool 1, Pool 2, Pool 3 block.
Fill in the pool addresses
Pool 1 — the recommended address (auto-select), Pool 2 and Pool 3 — two nearest locations. Worker — your login in the form subaccount.worker, Password — anything.
Save and check
Press Save & Apply, wait for the restart and check share submission on the Miner Status tab; accruals appear in the cabinet.
Announced in August 2025 and shipping from that autumn, the Antminer L11 is Bitmain's current air-cooled flagship for Litecoin and Dogecoin: about 20 GH/s at 184 J/GH, or 21 GH/s at 172 J/GH in the Pro trim.
Efficiency is the whole point. At any given power cost per kWh, the L11 turns more of each kilowatt into hashrate than any earlier air-cooled L-series miner, which matters most for farms paying market electricity rates.
On RuPool you configure only the LTC stratum; Dogecoin is merge-mined and credited automatically at its own FPPS rate. The USD estimate at the top of the page includes both coins.
The L11 takes single-phase 220–277 V and draws about 3.7 kW, roughly 88 kWh per day. A 120 V outlet will not run it; give each unit a dedicated 240 V circuit rated for continuous load, and balance several units across phases.
Noise is about 75 dB with front-to-back airflow. The chassis is close to the L9 in size, so existing shelving, ducting and sound boxes usually carry over. Keep intake air below 40 °C and vent the exhaust outdoors.
Bitmain also sells L11 Hyd 2U and 6U rack units with liquid cooling and three-phase input for data centers. Those are different machines; this page covers the air-cooled L11 and L11 Pro.
Stick with stock Bitmain firmware, updated from Bitmain's official site. Third-party firmware for new models arrives late and can void the warranty, so running stock until the warranty ends is the safer default.
It depends on Scrypt difficulty and LTC and DOGE prices. The live FPPS estimate at the top of this page is recalculated automatically; subtract about 88 kWh per day times your electricity rate.
Same air-cooled chassis. The Pro does 21 GH/s at 3612 W versus 20 GH/s at 3680 W for the standard L11, so it is slightly faster and slightly more efficient.
Use the LTC stratum URL for your region listed above, or the auto address with failover. Worker name is subaccount.worker; the password can be anything. No separate Dogecoin setup is needed.
About 88 kWh for the 20 GH/s L11 and about 87 kWh for the L11 Pro, based on manufacturer wall power.
The L11 is about 14% more efficient than the L9 and nearly twice as efficient as the L7. With expensive power the newer machine wins; with cheap power a used L9 may return its price sooner.
No. It needs 220–277 V single-phase input.
Sign up — your cabinet opens a step-by-step guide: create a subaccount, set a payout address and enter the stratum address in the miner.
Daily payouts, 1% FPPS fee, 24/7 support.