Antminer L9

LTC and DOGE mining (merged mining) on the RuPool pool · 16 GH/s, 3,360 W

≈ $5.53/day · covers power up to $0.069/kWh

Start mining

After sign-up your cabinet opens a step-by-step connection guide.

Specifications

ModeHashratePowerEfficiency
Antminer L9 16 GH/sprimary16 GH/s3,360 W210 J/GH
Antminer L9 17 GH/s17 GH/s3,570 W210 J/GH
Antminer L9 15 GH/s15 GH/s3,150 W210 J/GH
Manufacturer
Bitmain
Algorithm
Scrypt
Cooling
Air
Release year
2024
Noise level
75 dB
Voltage
220–277
Dimensions
400 × 195 × 290 mm
Weight
14.2 kg

Specification source

Profitability

ModeMined per dayRevenue per dayRevenue per monthPower useCovers power
Antminer L9 16 GH/s0.02019405 LTC79.23975186 DOGE$5.53$165.8480.6 kWhup to $0.069/kWh
Antminer L9 17 GH/s0.02145618 LTC84.19223635 DOGE$5.87$176.2185.7 kWhup to $0.069/kWh
Antminer L9 15 GH/s0.01893192 LTC74.28726736 DOGE$5.18$155.4875.6 kWhup to $0.069/kWh

LTC and DOGE are mined at the same time on the same hashrate (merged mining) — the income adds up.

Net profit, mode “Antminer L9 16 GH/s”

TariffProfit per dayProfit per month
$0.05/kWh$1.50$44.88
$0.08/kWh-$0.92-$27.69
$0.12/kWh-$4.15-$124.46

Calculated on 19 November 2026. Pool fee included. Rate: 1 LTC = $44.12, 1 DOGE = $0.05852.

Precise estimate in the profitability calculator

RuPool setup

Pool address, login and password to connect Antminer L9.

Recommended address — automatic location pick with failover

stratum+tcp://enter.rupool.pro:3334
Other ports (if the main one is blocked by your ISP)
stratum+tcp://enter.rupool.pro:8889
stratum+tcp://enter.rupool.pro:444
stratum+tcp://enter.rupool.pro:26
stratum+ssl://enter.rupool.pro:998
Addresses by location

Moscow (whitelist)

stratum+tcp://msk-ru.enter.rupool.pro:3334
Other ports (if the main one is blocked by your ISP)
stratum+tcp://msk-ru.enter.rupool.pro:8889
stratum+tcp://msk-ru.enter.rupool.pro:444
stratum+tcp://msk-ru.enter.rupool.pro:26
stratum+ssl://msk-ru.enter.rupool.pro:998

Moscow

stratum+tcp://msk2-ru.enter.rupool.pro:3334
Other ports (if the main one is blocked by your ISP)
stratum+tcp://msk2-ru.enter.rupool.pro:8889
stratum+tcp://msk2-ru.enter.rupool.pro:444
stratum+tcp://msk2-ru.enter.rupool.pro:26
stratum+ssl://msk2-ru.enter.rupool.pro:998

Novosibirsk

stratum+tcp://nsk-ru.enter.rupool.pro:3334
Other ports (if the main one is blocked by your ISP)
stratum+tcp://nsk-ru.enter.rupool.pro:8889
stratum+tcp://nsk-ru.enter.rupool.pro:444
stratum+tcp://nsk-ru.enter.rupool.pro:26
stratum+ssl://nsk-ru.enter.rupool.pro:998

Helsinki

stratum+tcp://hel-fi.enter.rupool.pro:3334
Other ports (if the main one is blocked by your ISP)
stratum+tcp://hel-fi.enter.rupool.pro:8889
stratum+tcp://hel-fi.enter.rupool.pro:444
stratum+tcp://hel-fi.enter.rupool.pro:26
stratum+ssl://hel-fi.enter.rupool.pro:998

Almaty

stratum+tcp://ala-kz.enter.rupool.pro:3334
Other ports (if the main one is blocked by your ISP)
stratum+tcp://ala-kz.enter.rupool.pro:8889
stratum+tcp://ala-kz.enter.rupool.pro:444
stratum+tcp://ala-kz.enter.rupool.pro:26
stratum+ssl://ala-kz.enter.rupool.pro:998
Login (worker):own.ltc_l7_1

Format: <subaccount>.<worker>. Get your subaccount in the cabinet.

Password:anything

Connect to the LTC stratum — DOGE is credited automatically (merged mining). No separate DOGE address or wallet is needed to connect.

How to set up Antminer L9 on the pool

  1. Find the miner IP

    Find the ASIC IP address in your router's DHCP client list, or press the IP Report button on the miner itself.

  2. Open the web interface

    Enter the IP address in a browser on a computer on the same network.

  3. Log in to the panel

    Default login and password on stock firmware are root / root.

  4. Open the pool settings

    Go to Miner Configuration → General Settings, the Pool 1, Pool 2, Pool 3 block.

  5. Fill in the pool addresses

    Pool 1 — the recommended address (auto-select), Pool 2 and Pool 3 — two nearest locations. Worker — your login in the form subaccount.worker, Password — anything.

  6. Save and check

    Press Save & Apply, wait for the restart and check share submission on the Miner Status tab; accruals appear in the cabinet.

The Antminer L9 is Bitmain's 2024 Scrypt workhorse for Litecoin and Dogecoin. It ships in 15, 16 and 17 GH/s bins that all run near 210 J/GH, so you pick a bin by how much power your circuit can deliver, not by efficiency.

On RuPool you point the L9 at the LTC stratum and the pool merge-mines Dogecoin on the same work. DOGE is credited automatically at its own FPPS rate: no second pool entry, no DOGE address on the miner. The USD figure above combines both coins.

It fits garages, small farms and air-cooled hosting. In a living space it needs a sound-dampening enclosure with ducted exhaust.

Input is single-phase 220–277 V at up to 20 A. A North American 120 V outlet will not run it; you need a dedicated 240 V circuit sized for continuous load. Daily energy use is roughly 76 kWh for the 15 GH/s bin and 86 kWh for the 17 GH/s bin — multiply by your price per kWh to get the daily power bill.

Expect about 75 dB and front-to-back airflow. The rated intake range goes up to 45 °C, but chips run happier at 20–30 °C, so duct hot exhaust outside instead of letting it recirculate.

Against the older L7 (about 9.5 GH/s at ~360 J/GH) the L9 nearly doubles hashrate at similar wall power. The newer L11 reaches about 20 GH/s at ~184 J/GH, which makes the L9 the middle ground between purchase price and efficiency.

Stock Bitmain firmware gives you three pool slots and temperature and hashrate monitoring. Download updates only from Bitmain. Third-party firmware exists; whether to use it is your call, keeping warranty in mind.

Frequently asked questions

How much does an Antminer L9 earn per day?

It depends on Scrypt network difficulty and LTC and DOGE prices. The live FPPS estimate at the top of this page updates automatically and includes both coins. Subtract your electricity cost at 3.15–3.57 kW depending on the bin.

Do I need to set up Dogecoin separately?

No. Point the L9 at RuPool's LTC stratum and DOGE is credited automatically at its own rate — no extra pool, no DOGE address in the miner config.

What are the L9 pool settings for RuPool?

Use the stratum URL for your region shown above (or the auto address with failover), worker name subaccount.worker, and any password. Save in the Antminer web UI and the worker shows up in your dashboard within minutes.

How much electricity does the Antminer L9 use?

3150 W for the 15 GH/s bin, 3360 W for 16 GH/s and 3570 W for 17 GH/s — about 76 to 86 kWh per day.

Is the L11 worth it over the L9?

The L11 delivers roughly 14% more hashrate per watt. Whether that pays for the higher price depends on your electricity cost; compare the live numbers on both model pages.

Can the Antminer L9 run on 120 V?

No. Bitmain specifies 220–277 V single-phase input. Running it on a lower voltage risks damaging the power supply.

Connect Antminer L9 to RuPool

Sign up — your cabinet opens a step-by-step guide: create a subaccount, set a payout address and enter the stratum address in the miner.

Daily payouts, 1% FPPS fee, 24/7 support.

Start mining