BTC mining on the RuPool pool · 186 TH/s, 3,441 W
≈ $5.34/day · covers power up to $0.065/kWh
After sign-up your cabinet opens a step-by-step connection guide.
| Mode | Hashrate | Power | Efficiency |
|---|---|---|---|
| Whatsminer M60S 186 TH/sprimary | 186 TH/s | 3,441 W | 18.5 J/TH |
| Whatsminer M60S 180 TH/s | 180 TH/s | 3,330 W | 18.5 J/TH |
| Whatsminer M60 172 TH/s | 172 TH/s | 3,423 W | 19.9 J/TH |
| Whatsminer M60 168 TH/s | 168 TH/s | 3,343 W | 19.9 J/TH |
| Mode | Mined per day | Revenue per day | Revenue per month | Power use | Covers power |
|---|---|---|---|---|---|
| Whatsminer M60S 186 TH/s | 0.00008545 BTC | $5.34 | $160.31 | 82.6 kWh | up to $0.065/kWh |
| Whatsminer M60S 180 TH/s | 0.00008269 BTC | $5.17 | $155.14 | 79.9 kWh | up to $0.065/kWh |
| Whatsminer M60 172 TH/s | 0.00007901 BTC | $4.94 | $148.25 | 82.2 kWh | up to $0.06/kWh |
| Whatsminer M60 168 TH/s | 0.00007718 BTC | $4.83 | $144.80 | 80.2 kWh | up to $0.06/kWh |
| Tariff | Profit per day | Profit per month |
|---|---|---|
| $0.05/kWh | $1.21 | $36.44 |
| $0.08/kWh | -$1.26 | -$37.89 |
| $0.12/kWh | -$4.57 | -$136.99 |
Calculated on 18 November 2026. Pool fee included. Rate: 1 BTC = $62,539.90.
Precise estimate in the profitability calculatorPool address, login and password to connect Whatsminer M60S.
Recommended address — automatic location pick with failover
stratum+tcp://enter.rupool.pro:3333stratum+tcp://enter.rupool.pro:8888stratum+tcp://enter.rupool.pro:443stratum+tcp://enter.rupool.pro:25stratum+ssl://enter.rupool.pro:999Moscow (whitelist)
stratum+tcp://msk-ru.enter.rupool.pro:3333stratum+tcp://msk-ru.enter.rupool.pro:8888stratum+tcp://msk-ru.enter.rupool.pro:443stratum+tcp://msk-ru.enter.rupool.pro:25stratum+ssl://msk-ru.enter.rupool.pro:999Moscow
stratum+tcp://msk2-ru.enter.rupool.pro:3333stratum+tcp://msk2-ru.enter.rupool.pro:8888stratum+tcp://msk2-ru.enter.rupool.pro:443stratum+tcp://msk2-ru.enter.rupool.pro:25stratum+ssl://msk2-ru.enter.rupool.pro:999Novosibirsk
stratum+tcp://nsk-ru.enter.rupool.pro:3333stratum+tcp://nsk-ru.enter.rupool.pro:8888stratum+tcp://nsk-ru.enter.rupool.pro:443stratum+tcp://nsk-ru.enter.rupool.pro:25stratum+ssl://nsk-ru.enter.rupool.pro:999Helsinki
stratum+tcp://hel-fi.enter.rupool.pro:3333stratum+tcp://hel-fi.enter.rupool.pro:8888stratum+tcp://hel-fi.enter.rupool.pro:443stratum+tcp://hel-fi.enter.rupool.pro:25stratum+ssl://hel-fi.enter.rupool.pro:999Almaty
stratum+tcp://ala-kz.enter.rupool.pro:3333stratum+tcp://ala-kz.enter.rupool.pro:8888stratum+tcp://ala-kz.enter.rupool.pro:443stratum+tcp://ala-kz.enter.rupool.pro:25stratum+ssl://ala-kz.enter.rupool.pro:999own.152Format: <subaccount>.<worker>. Get your subaccount in the cabinet.
Find the miner IP
Find the Whatsminer IP in the router's client list or via the WhatsMinerTool utility.
Open the web interface
Enter the IP address in a browser; default login and password are admin / admin.
Open the pool settings
Go to Configuration → Pools (CGMiner configuration).
Fill in the pool addresses
Pool 1 — the recommended address (auto-select), Pool 2 and Pool 3 — two nearest locations. Worker — a login in the form subaccount.worker, Password — anything.
Save and restart
Press Save/Apply and wait for the miner to restart; check the status in the panel and accruals in the cabinet.
The Whatsminer M60 and M60S are MicroBT's current-class air-cooled Bitcoin miners, introduced in late 2023. The M60 is rated around 19.9 J/TH and the M60S around 18.5 J/TH, putting them in the same efficiency league as Bitmain's S21 generation.
For operators without three-phase power, the M60S is one of the more practical modern options: an integrated 220–240 V supply, a single C19 cord and the same chassis dimensions as the M50, so existing racks and ducting usually fit.
On RuPool the M60 and M60S mine Bitcoin (SHA-256) and are paid FPPS on every accepted share, so revenue follows hashrate rather than block luck.
Each unit draws roughly 3.3 to 3.5 kW through a built-in P221B/P222B supply rated for 220–240 V. In the US or Canada that means a dedicated 240 V circuit sized for continuous load, one miner per circuit.
MicroBT rates the M60 series for −5 to 35 °C ambient and does not support adding extra fans. Two fans produce about 75 dB, so hot climates need serious exhaust capacity and winter setups should keep snow and condensation out of the intake.
The M60S improves on the M60 by about 1.4 J/TH. The later M60S+ and M60S++ go further, and hydro variants exist as separate models. Against an Antminer T21 the M60S is slightly more efficient and, crucially, single-phase.
Pool settings, firmware updates and error codes are available in the web interface and in MicroBT's WhatsMinerTool. Stock MicroBT firmware is recommended as the baseline; RuPool accepts any firmware using standard stratum.
The M60S is more efficient, around 18.5 J/TH versus about 19.9 J/TH for the M60, with the same chassis and power supply. At equal hashrate it costs less to run; the M60 makes sense only at a meaningfully lower price.
It depends on network difficulty and the Bitcoin price. The live FPPS estimate at the top of this page is recalculated automatically for the variant you select.
A 186 TH/s unit at about 3441 W uses around 83 kWh per day. Multiply by your electricity rate per kWh to get the daily cost.
No. It runs on 220–240 V single-phase with a C19 cord rated 16 A or more. That is its main practical advantage over three-phase-only miners like the Antminer T21.
Open the miner's IP in a browser or use WhatsMinerTool, go to the pool settings, enter a RuPool stratum address from this page, set the worker as subaccount.worker and any password, then save and restart if prompted.
MicroBT specifies −5 to 35 °C. Above that the miner protects itself by throttling or stopping, so plan exhaust and intake airflow for your hottest days.
Sign up — your cabinet opens a step-by-step guide: create a subaccount, set a payout address and enter the stratum address in the miner.
Daily payouts, 1% FPPS fee, 24/7 support.